36W 100~240V 50-60Hz Power supply adaptor folded plug US plug Deatchable AC plug LXCP37

The purpose of the document is to specify the functional requirements of a LXCP37 series switching power supply.

    Input Characteristics

    Input Voltage:

    Nominal Voltage: 100~240Vac

    Variation Range: 90~264Vac

    Input Frequency:

    Nominal Frequency: 50/60Hz.

    Variation Frequency: 47~63Hz

    Input Current:

    0.9Amps max at any input voltage and rated DC output and rated load.

    Inrush Current:

    60Amps Max. Cold start at 264Vac input, with rated load and 25℃ ambient.

    AC Leakage Current:

    Normal 0.1mA Max.at 264Vac input.

    Sing le fault 0.2mA Max.at 264Vac input.

    Output Characteristics

    Model name

    Qutput voltage(V)

    Rated load(A)

    Output range(V)

    Over current protection(A)

    Efficien

    cy (%)

    Output power(W)

    LXCP37-050

    5.0

    6.00

    4.40~5.60

    ≤12.0

    70

    30.0

    LXCP37-075

    7.5

    4.80

    6.90~8.10

    ≤9.6

    70

    36.0

    LXCP37-090

    9.0

    4.00

    8.40~9.60

    ≤8.0

    72

    36.0

    LXCP37-120

    12.0

    3.00

    11.40~ 12.60

    ≤6.0

    82

    36.0

    LXCP37-135

    13.5

    2.66

    12.90~ 14.10

    ≤5.0

    82

    36.0

    LXCP37-150

    15.0

    2.40

    14.40~ 15.60

    ≤5.0

    82

    36.0

    LXCP37-168

    16.8

    2.14

    16.20~ 17.40

    ≤4.0

    82

    36.0

    LXCP37-180

    18.0

    2.00

    17.40~ 18.60

    ≤4.0

    84

    36.0

    LXCP37-190

    19.0

    1.89

    18.40~ 19.60

    ≤3.6

    84

    36.0

    LXCP37-200

    20.0

    1.80

    19.40~20.60

    ≤3.6

    84

    36.0

    LXCP37-240

    24.0

    1.50

    23.40~24.60

    ≤3.0

    84

    36.0

    Line regulation

    ±3%

    Load regulation

    ±8%

    Ripple and Noise

    Under nominal voltage and rated load, the ripple and noise are less than 200mVp-p when measure with Max. Bandwidth of 20MHz and parallel 10uF+0.1uF, connected at testing point.

    Turn on delay time

    3 Second Max.at 220Vac input and output rated load.

    Rise time

    50ms Max.at 115Vac input and output rated load.

    Hold up time

    5mS Min.at 115Vac input and output rated Load.

    Efficiency:

    70% Min, at 115/230Vac input voltage, rated load,Test USB end of power supply

    Protection Function

    Short circuit test

    The power supply will be auto recovering when short circuit faults removed.

    Over current Protection

    When the output current exceeds 110% to 200% of the rated current, the power supply will activate protection. Once the overcurrent fault is resolved, the power supply will automatically restore operation.

    Over Voltage Protection

    When the IC's temperature exceeds its trigger point, the power supply will enter stop mode. Once the IC temperature falls below the regulation value, the power supply will automatically recover.

    Environmental Requiremet

    Operating Temperature

    0℃ to 40℃,Rated load, Normal operation.

    Storage Temperature:-20℃ to 80℃

    With package

    Storage Humidity: 10%~90%

    No condensation

    Atmospheric pressure

    70-106KPa, Normal.

    Altitude

    5000m,Work temp descend 1℃ every 300m over 5000m.

    5~9Hz,Amplitude of vibration=3.5mm
    9~200Hz,Acceleration=5m/S2
    200~500Hz,Acceleration=15m/S2

    Transportation: 5-9Hz, A=3.5mm

    Acceleration=5m/S2

    Acceleration=15m/S2

    Axes, 10 cycles per axis

    No permanent damage may occur during testing.

    The Power supply can be restore to normal after power off/on.

    Dropping Packed

    The wall mount type requires 1m, and the desktop type requires 760mm, as described above.

    The horizontal surface should be made of hardwood at least 13mm thick, mounted on two layers of plywood, and positioned 19mm to 20mm away from the edge.

    Relative Humidity

    5%(0℃) ~90%(40℃)RH, 72Hrs, Rated load, Normal operating.

    MTBF

    The power supply is expected to have a minimum Mean Time Between Failures (MTBF) of 100,000 hours under normal operating conditions and typical usage.

    Electromagnetic Compatiblity

    Numbe

    Item

    Specifications

    Class

    Standards

    1

    (CE)

    CLASS B

    /

    IEC/EN60601-1-2; YY0505

    GB4824; EN55011;

    FCC Part 18

    2

    (RE)

    CLASS B

    /

    IEC/EN60601-1-2; YY0505

    GB4824; EN55011;

    FCC Part 18

    3

    (SURGE)

    Line to line±1KV

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-5; GB17626.5

     

     

    Line to GND±2KV

    A

     

    4

    (ESD)

    Air discharge±15KV

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-2; GB17626.2

     

     

    Contact discharge±8KV

    A

     

    5

    (EFT/B)

    ±2KV (BURST FREQUENCY=100KHZ)

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-4; GB17626.4

    6

    (DIP)

    Dropped to 0%Ut,last 5000ms(250cycle)

    B

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-11; GB17626.11

    Dropped to 30%Ut,last 500ms(25 cycle)

    B

     

    Dropped to 0%Ut,last 20ms(1 cycle)

    B

     

    Dropped to0%Ut,last 10ms(0.5 cycle)

    A

     

    7

    (RS)

    Test frequency:80MHz~2700MHz;

    Field intensity:10V/m;80%AM(1KHz)

    Amplitude modulation:80%AM(1KHz)

    A

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-3; GB17626.3

    8

    (CS)

    Test frequency:0.15MHz~80MHz;

    Field intensity:6Vrms;

    Amplitude modulation:80%AM(1KHz)

    A

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-6; GB17626.6

    9

    (THD)

    CLASSA(in system)

    /

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-3-2; GB17625.1

    10

    Voltage

    Fluctuation and Flicker

    Pst≤1.0;Plt≤0.65;Relative steady-state voltage variation dc under3.3%;Maximum relative voltage variation (dmax) under4%

    /

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-3-3; GB17625.2

    11

    Power Frequency Magnetic Field

    30A/m

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-8; GB17626.8

    Performance criterion A: Normal performance within limits in this specification. 
    Performance criterion B: Temporary loss of some functions or degradation of performance. The recovering performance of which without operator intervention.
    Performance Criterion C: Temporary loss of function or reduced performance that requires operator intervention for recovery.
    Performance Criterion D: Permanent loss of function or reduced performance due to hardware or software damage, or data loss, which is not recoverable.

    Safety: accord with

    The power supply is intended for indoor use and is designed to comply with the safety standards of IEC 60601-1 and EN 60601-1, as well as other relevant safety regulations.
     

    ITEM

    COUNTRY

    STANDARD

    UL

    USA

    UL60950-1/UL60601-1

    CE

    EUROPE

    EN60950-1/EN60601-1

    CB

    WORLDWIDE

    IEC60601-1

    TUV

    GERMANY

    IEC60601-1

    NRTL

    CUSA

    IEC60601-1/UL60601-1

    GS

    GERMANY

    EN60601-1

    BS

    ENGLAND

    EN60601-1

    SAA

    AUSTRALIA

    AS/NZS6-1

    The primary to secondary: 4000Vac 10mA for 60 seconds

    Mechanical Requirement

    LF~$SNHHN]C(A~~@~F3A[9Mhs0

    optional DC plug 

    optional DC plug  (1)skdoptional DC plug  (2)j9doptional DC plug  (3)k9yoptional DC plug  (4)1kd
    Note: Details are selected from the LXC_ Wire Library drawing XLS file

    Label

    `ZVX(VU$WUU69%HXSZZ57ttv

    Certificate

    Our company has passed ISO 9001:2015, ISO 13485:2016 quality management system certification, products and production process to achieve RoHS environmental protection requirements, in line with ISO14001 environmental management system; Our products have passed UL, CE, CSA, TUV, CB and other certifications, and they are exported to the United States, Britain, Germany, France, Italy, Singapore, Argentina, Brazil, India and other countries.