Leave Your Message
Products Categories
Featured Products

30W medical power supply single open frame output DC 12V2.5A 24V1.3A for Endoscopy Patient Monitor ACMS23

The power supplydesign for medical equipments and rang of input voltage acoording to global power grid.

The functions of protection are output current limited shorted and overvoltage,etc;

Lower ripple wave and spike noise

    Normative reference

    IEC68-2-1 IEC68-2-1A GB2423.1

    Basic environmental testing procedures for electric and electronic products - Test A: Low temperature test method;

    IEC68-2-2 IEC68-2-2A GB2423.2

    Basic environmental testing procedures for electric and electronic products - Test B: Dry hear;

    IEC68-2-3 GB2423.9

    Basic environmental test procedure for electrical and electronic products Test Cd: Damp heat, steady state, primarily for equipment

    IEC68-2-6 GB2423.10

    Basic environmental testing procedures for electric and electronic products Test Fc and guidance:Vibration sinusoidal

    IEC60601-1 GB 9706.1

    Medical electrical equipment - part 1: general requirements for safety;

    IEC60601-1-2 YY0505

    IEC60601-1-2 YY0505Medical electrical equipment - part 1-2: common safety requirements and standards: electromagnetic compatibility requirements and tests.

    Input characteristics

    Number

    Item

    Specifications

    Unit

    Note

    1

    Normal input

    220

    Vac

    2

    Range

    100~240

    Vac

    3

    Frequencry

    50/60

    Hz

    4

    Current max

    0.7

    A

    90Vac,25℃

    5

    Inrush current

    ≤60

    A

    220Vac,25℃

    ≤30

     

    115Vac,25℃

    Item

    Model number

    OUTPUT CHARACTERISTICS

    Rated output voltage

    (v)

    Output voltage range

    (V)

    Output currentrange

    (A)

    Model number(High power version with radiator)

    ACMS23-005

    5.0

    4.70~5.30

    0-4.00

    ACMS23-075

    7.5

    7.20~7.80

    0-3.00

    ACMS23-009

    9.0

    8.55~9.45

    0-3.00

    ACMS23-012

    12.0

    11.64~12.36

    0-2.50

    ACMS23-136

    13.6

    13.30~13.90

    0-2.20

    ACMS23-142

    14.2

    13.90~14.50

    0-2.10

    ACMS23-015

    15.0

    14.70~15.30

    0-2.00

    ACMS23-168

    16.8

    16.46~17.13

    0-1.78

    ACMS23-018

    18.0

    17.80~18.20

    0-1.66

    ACMS23-019

    19.0

    18.70~19.30

    0-1.57

    ACMS23-020

    20.0

    19.70~20.30

    0-1.50

    ACMS23-024

    24.0

    23.50~24.50

    0-1.30

    Model number(version without radiator)

     

    ACMS23-005

    5.0

    4.70~5.30

    0-3.00

    ACMS23-075

    7.5

    7.20~7.80

    0-2.50

    ACMS23-009

    9.0

    8.55~9.45

    0-2.50

    ACMS23-012

    12.0

    11.64~12.36

    0-2.10

    ACMS23-136

    13.6

    13.30~13.90

    0-1.83

    ACMS23-142

    14.2

    13.90~14.50

    0-1.76

    ACMS23-015

    15.0

    14.70~15.30

    0-1.67

    ACMS23-168

    16.8

    16.46~17.13

    0-1.49

    ACMS23-018

    18.0

    17.80~18.20

    0-1.39

    ACMS23-019

    19.0

    18.70~19.30

    0-1.32

    ACMS23-020

    20.0

    19.70~20.30

    0-1.25

    ACMS23-024

    24.0

    23.50~24.50

    0-1.10

    load regulation

    ±3%

    voltage regulation

    ±3%

    overshoot

    ≤5%

    Hold up time

    ≥10 mS

    Ripple and noise

    ≤100mV (measured by 20MHz bandwidth oscilloscope and terminated each output with a 0.1uF ceramic capacitor and a10uF aluminum electrolytic capacitor)

    Over voltage protection

    110-150%Vout

    Over current protection

    110-170%Iout

    Over temperature protection

    The power supply shall go into stop mode when the IC's temperature is over its trigger point and when IC temperature is lower than regulation value, the power supply shall be self-recovering.

    Short circuit protection

    The power supply shall withstand continuous current of short circuit on output no any damage, and when the fault condition is removed, the power supply shall be self-recovering.

    Electromagnetic Compatiblity

    Numbe

    Item

    Specifications

    Class

    Standards

    1

    (CE)

    CLASS B

    /

    IEC/EN60601-1-2; YY0505

    GB4824; EN55011;

    FCC Part 18

    2

    (RE)

    CLASS B

    /

    IEC/EN60601-1-2; YY0505

    GB4824; EN55011;

    FCC Part 18

    3

    (SURGE)

    Line to line±1KV

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-5; GB17626.5

     

     

    Line to GND±2KV

    A

     

    4

    (ESD)

    Air discharge±15KV

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-2; GB17626.2

     

     

    Contact discharge±8KV

    A

     

    5

    (EFT/B)

    ±2KV (BURST FREQUENCY=100KHZ)

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-4; GB17626.4

    6

    (DIP)

    Dropped to 0%Ut,last 5000ms(250cycle)

    B

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-11; GB17626.11

    Dropped to 30%Ut,last 500ms(25 cycle)

    B

     

    Dropped to 0%Ut,last 20ms(1 cycle)

    B

     

    Dropped to0%Ut,last 10ms(0.5 cycle)

    A

     

    7

    (RS)

    Test frequency:80MHz~2700MHz;

    Field intensity:10V/m;80%AM(1KHz)

    Amplitude modulation:80%AM(1KHz)

    A

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-3; GB17626.3

    8

    (CS)

    Test frequency:0.15MHz~80MHz;

    Field intensity:6Vrms;

    Amplitude modulation:80%AM(1KHz)

    A

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-6; GB17626.6

    9

    (THD)

    CLASSA(in system)

    /

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-3-2; GB17625.1

    10

    Voltage

    Fluctuation and Flicker

    Pst≤1.0;Plt≤0.65;Relative steady-state voltage variation dc under3.3%; Maximum relative voltage variation (dmax) under4%

    /

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-3-3; GB17625.2

    11

    Power Frequency Magnetic Field

    30A/m

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-8; GB17626.8

    The power supply can  be operated normaly.
    The power supplytemporary decline or loss of function or performance but free Recoverability. 
    The power supplytemporary decline or loss of function or performance butforceRecoverability.
    The power supplyloss of function or performance forever.

    Outline

    US ping the power supply size: L 40.5 x W 34.7 x H 24.1mm;
    asd 37gv0

    Label

    aiuhsdg (1)3txaiuhsdg (2)cxnaiuhsdg (3)43h
    aiuhsdg (4)olbaiuhsdg (5)xrhaiuhsdg (6)ijb
    aiuhsdg (7)6wgaiuhsdg (8)i5jaiuhsdg (9)pd4
    aiuhsdg (13)f04aiuhsdg (14)96taiuhsdg (15)prh