300W Longxc AC/DC Open-frame Industry Medical 24V/300W Switching Power Supply ACMS240
Normative reference
Number |
Item |
Specifications |
Unit |
Note |
1 |
Operating temperature |
-10~+40 |
℃ |
|
2 |
Relative humidity |
10~90 |
% |
No condensation |
3 |
Atmospheric pressure |
54~106 |
KPa |
Normal |
4 |
Operating Altitude |
≤5000 |
m |
Work temp descend 1℃ every 300m over 5000m |
6 |
Pollution levels |
I |
|
output characteristics
Number |
Model name |
Output voltage (Vdc) |
With fan |
Without fan |
||
Output current (A) |
Output Power (W) |
Output current (A) |
Output Power (W) |
|||
1 |
ACMS200-120 |
12.0 |
0-17.0 |
204.0 |
0-12.0 |
144.0 |
2 |
ACMS200-135 |
13.5 |
0-15.0 |
202.5 |
0-10.4 |
140.0 |
3 |
ACMS200-150 |
15.0 |
0-13.4 |
201.0 |
0-9.4 |
140.0 |
4 |
ACMS200-168 |
16.8 |
0-12.0 |
201.6 |
0-8.4 |
140.0 |
5 |
ACMS200-180 |
18.0 |
0-11.2 |
201.6 |
0-7.8 |
140.0 |
6 |
ACMS200-190 |
19.0 |
0-10.6 |
201.4 |
0-7.4 |
140.6 |
7 |
ACMS200-200 |
20.0 |
0-10.0 |
200.0 |
0-7.0 |
140.0 |
8 |
ACMS200-240 |
24.0 |
0-8.4 |
201.6 |
0-5.9 |
141.6 |
9 |
ACMS200-260 |
26.0 |
0-7.7 |
200.0 |
0-5.4 |
140.0 |
10 |
ACMS200-280 |
28.0 |
0-7.2 |
201.6 |
0-5.0 |
140.0 |
11 |
ACMS200-300 |
30.0 |
0-6.7 |
201.0 |
0-4.7 |
141.0 |
12 |
ACMS200-320 |
32.0 |
0-6.3 |
201.6 |
0-4.4 |
140.8 |
13 |
ACMS200-360 |
36.0 |
0-5.6 |
201.6 |
0-3.9 |
140.0 |
14 |
ACMS200-380 |
38.0 |
0-5.3 |
201.4 |
0-3.7 |
140.6 |
15 |
ACMS200-400 |
40.0 |
0-5.0 |
200.0 |
0-3.5 |
140.0 |
16 |
ACMS200-420 |
42.0 |
0-4.8 |
201.6 |
0-3.3 |
142.8 |
17 |
ACMS200-460 |
46.0 |
0-4.4 |
202.4 |
0-3.1 |
142.6 |
18 |
ACMS200-480 |
48.0 |
0-4.3 |
206.4 |
0-3.0 |
144.0 |
Rated power |
With fan |
200W |
||||
Without fan |
140W |
|||||
Load regulation |
±1% |
|||||
Voltage regulation |
±2% |
|||||
Overshoot |
≤5% |
|||||
Hold up time |
≥10 mS |
|||||
Efficiency |
92% |
|||||
Ripple and noise |
≤200mV (measured by 20MHz bandwidth oscilloscope and terminated each output with a 0.1uF ceramic capacitor and a10uF aluminum electrolytic capacitor) |
|||||
Short circuit protection |
The power supply shall withstand continuous current of short circuit on output no any damage, and when the fault condition is removed, the power supply shall be self-recovering. |
Notice
Check
Check whether the power supply is damaged intransportation before usedPreservation of package materials until all the units have been cheked and registed.
Use principle
Warning
Electromagnetic Compatiblity
Numbe |
Item |
Specifications |
Class |
Standards |
1 |
(CE) |
CLASS B |
/ |
IEC/EN60601-1-2; YY0505 GB4824; EN55011; FCC Part 18 |
2 |
(RE) |
CLASS B |
/ |
IEC/EN60601-1-2; YY0505 GB4824; EN55011; FCC Part 18 |
3 |
(SURGE) |
Line to line±1KV |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-5; GB17626.5 |
|
|
Line to GND±2KV |
A |
|
4 |
(ESD) |
Air discharge±15KV |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-2; GB17626.2 |
|
|
Contact discharge±8KV |
A |
|
5 |
(EFT/B) |
±2KV (BURST FREQUENCY=100KHZ) |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-4; GB17626.4 |
6 |
(DIP) |
Dropped to 0%Ut,last 5000ms(250cycle) |
B |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-11; GB17626.11 |
Dropped to 30%Ut,last 500ms(25 cycle) |
B |
|
||
Dropped to 0%Ut,last 20ms(1 cycle) |
B |
|
||
Dropped to0%Ut,last 10ms(0.5 cycle) |
A |
|
||
7 |
(RS) |
Test frequency:80MHz~2700MHz; Field intensity:10V/m;80%AM(1KHz) Amplitude modulation:80%AM(1KHz) |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-3; GB17626.3 |
8 |
(CS) |
Test frequency:0.15MHz~80MHz; Field intensity:6Vrms; Amplitude modulation:80%AM(1KHz) |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-6; GB17626.6 |
9 |
(THD) |
CLASSA(in system) |
/ |
IEC/EN60601-1-2; YY0505 IEC/EN61000-3-2; GB17625.1 |
10 |
Voltage Fluctuation and Flicker |
Pst≤1.0;Plt≤0.65;Relative steady-state voltage variation dc under3.3%;Maximum relative voltage variation (dmax) under4% |
/ |
IEC/EN60601-1-2; YY0505 IEC/EN61000-3-3; GB17625.2 |
11 |
Power Frequency Magnetic Field |
30A/m |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-8; GB17626.8 |
Others
Number |
Item |
Specifications |
1 |
Fault impact |
The power supply willeftin fault and no harmful to anthing else. |
2 |
Components |
The component the device above industrial leve |
3 |
Audible noise |
45dB(A),distance 1m |
4 |
Cooling Mode |
Free air convection |