Leave Your Message
Products Categories
Featured Products

300W Longxc AC/DC Open-frame Industry Medical 24V/300W Switching Power Supply ACMS240

The power supplydesign for medical equipments and rang of input voltage according to global power grid.

The functions of protection are output current limited shorted and overvoltageetc.

Lower ripple wave and spike noise.

    Normative reference

    IEC68-2-1 IEC68-2-1A GB2423.1
    Basic environmental testing procedures for electric and electronic products - Test A: Low temperature test method;
    IEC68-2-2 IEC68-2-2A GB2423.2
    Basic environmental testing procedures for electric and electronic products - Test B: Dry hear; IEC68-2-3 GB2423.9
    Basic environmental test procedure for electrical and electronic products Test Cd: Damp heat, steady state, primarily for equipment
    IEC68-2-6 GB2423.10
    Basic environmental testing  procedures for electric and electronic  products Test  Fc  and  guidance: Vibration  sinusoidal
    IEC60601-1 GB 9706.1
    Medical electrical equipment - part 1: general requirements for safety;
    IEC60601-1-2 YY0505
    Medical electrical equipment - part 1-2: common safety requirements and standards: electromagnetic compatibility requirements and tests.

    Number

    Item

    Specifications

    Unit

    Note

    1

    Operating temperature

    -10~+40

     

    2

    Relative humidity

    10~90

    %

    No condensation

    3

    Atmospheric pressure

    54~106

    KPa

    Normal

    4

    Operating Altitude

    ≤5000

    m

    Work  temp  descend  1℃ every  300m  over 5000m

    6

    Pollution levels

    I

     

     

    output characteristics

     

    Number

     

    Model name

    Output voltage  (Vdc)

    With fan

    Without fan

    Output current

    (A)

    Output Power

    (W)

    Output current

    (A)

    Output    Power (W)

    1

    ACMS200-120

    12.0

    0-17.0

    204.0

    0-12.0

    144.0

    2

    ACMS200-135

    13.5

    0-15.0

    202.5

    0-10.4

    140.0

    3

    ACMS200-150

    15.0

    0-13.4

    201.0

    0-9.4

    140.0

    4

    ACMS200-168

    16.8

    0-12.0

    201.6

    0-8.4

    140.0

    5

    ACMS200-180

    18.0

    0-11.2

    201.6

    0-7.8

    140.0

    6

    ACMS200-190

    19.0

    0-10.6

    201.4

    0-7.4

    140.6

    7

    ACMS200-200

    20.0

    0-10.0

    200.0

    0-7.0

    140.0

    8

    ACMS200-240

    24.0

    0-8.4

    201.6

    0-5.9

    141.6

    9

    ACMS200-260

    26.0

    0-7.7

    200.0

    0-5.4

    140.0

    10

    ACMS200-280

    28.0

    0-7.2

    201.6

    0-5.0

    140.0

    11

    ACMS200-300

    30.0

    0-6.7

    201.0

    0-4.7

    141.0

    12

    ACMS200-320

    32.0

    0-6.3

    201.6

    0-4.4

    140.8

    13

    ACMS200-360

    36.0

    0-5.6

    201.6

    0-3.9

    140.0

    14

    ACMS200-380

    38.0

    0-5.3

    201.4

    0-3.7

    140.6

    15

    ACMS200-400

    40.0

    0-5.0

    200.0

    0-3.5

    140.0

    16

    ACMS200-420

    42.0

    0-4.8

    201.6

    0-3.3

    142.8

    17

    ACMS200-460

    46.0

    0-4.4

    202.4

    0-3.1

    142.6

    18

    ACMS200-480

    48.0

    0-4.3

    206.4

    0-3.0

    144.0

     

    Rated

    power

    With fan

    200W

    Without fan

    140W

    Load regulation

    ±1%

    Voltage regulation

    ±2%

    Overshoot

    ≤5%

    Hold up time

    ≥10 mS

    Efficiency

    92%

    Ripple and noise

    ≤200mV (measured by 20MHz bandwidth oscilloscope and terminated each output with a 0.1uF

    ceramic capacitor and a10uF aluminum electrolytic capacitor)

    Short circuit protection

    The power supply shall withstand continuous current of short circuit on output no any damage, and

    when the fault condition is removed, the power supply shall be self-recovering.

    Notice

    Check

    Check whether the power supply is damaged intransportation before usedPreservation of package materials until all the units have been cheked and registed.

    Use principle

    1. When the power supply working, the air convection will be free. 2. The power supply shall be used under the environmental conditions specified in the specifications. 3. The componmentsinthe power supply should not be adjusted at all; 4. Do not operate in a volatile gas or flammable environment 5. Never remove the outer cover or touch the inner parts. 6. Do not carry out internal parts replacement separately; 7. Turn off the power supply immediately when smoke or unpleasant odor is found in the process of power-on.

    Warning

    1. Once the safety protection of the power supply is damaged, the power supply must be stopped working and be handled with reference to the relevant it’s self and System EUT specifications.
    2. When the power supply equipment changes from cold to warm environment the condensation may cause leakage hazar.So the grounding must be strictly enforced.
    3. Qualified personnel are required to connect the power supply to the input power.
    4. We need to maintain the power supply equipment after being Cuted off the input power and lasting for five minute for the capacitor having sufficient discharge time.
    5. Pay attention to safety logo. Do nottuch the areas with safety logos and danger logos

    Electromagnetic Compatiblity

    Numbe

    Item

    Specifications

    Class

    Standards

    1

    (CE)

    CLASS B

    /

    IEC/EN60601-1-2; YY0505

    GB4824; EN55011;

    FCC Part 18

    2

    (RE)

    CLASS B

    /

    IEC/EN60601-1-2; YY0505

    GB4824; EN55011;

    FCC Part 18

    3

    (SURGE)

    Line to line±1KV

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-5; GB17626.5

     

     

    Line to GND±2KV

    A

     

    4

    (ESD)

    Air discharge±15KV

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-2; GB17626.2

     

     

    Contact discharge±8KV

    A

     

    5

    (EFT/B)

    ±2KV (BURST FREQUENCY=100KHZ)

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-4; GB17626.4

    6

    (DIP)

    Dropped to 0%Ut,last 5000ms(250cycle)

    B

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-11; GB17626.11

    Dropped to 30%Ut,last 500ms(25 cycle)

    B

     

    Dropped to 0%Ut,last 20ms(1 cycle)

    B

     

    Dropped to0%Ut,last 10ms(0.5 cycle)

    A

     

    7

    (RS)

    Test frequency:80MHz~2700MHz;

    Field intensity:10V/m;80%AM(1KHz)

    Amplitude modulation:80%AM(1KHz)

    A

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-3; GB17626.3

    8

    (CS)

    Test frequency:0.15MHz~80MHz;

    Field intensity:6Vrms;

    Amplitude modulation:80%AM(1KHz)

    A

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-6; GB17626.6

    9

    (THD)

    CLASSA(in system)

    /

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-3-2; GB17625.1

    10

    Voltage

    Fluctuation and Flicker

    Pst≤1.0;Plt≤0.65;Relative steady-state voltage variation dc under3.3%;Maximum relative voltage variation (dmax) under4%

    /

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-3-3; GB17625.2

    11

    Power Frequency Magnetic Field

    30A/m

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-8; GB17626.8

    Class A:The power supply can be operated normal.
    Class B:The power supplytemporary decline or loss of function or performance but freeRecoverability.
    Class C:The power supplytemporary decline or loss of function or performance butforceRecoverability.
    Class D:The power supplyloss of function or performance forever.

    Others

    Number

    Item

    Specifications

    1

    Fault impact

    The power supply willeftin fault and no harmful to anthing else.

    2

    Components

    The component the device above industrial leve

    3

    Audible noise

    45dB(A),distance 1m

    4

    Cooling Mode

    Free air convection

    Cable

    asdsss 24m7k